TFAB – Tannas Foam Air Bath-环球(香港)科技有限公司
Product
Location:Home > Our Products > Manufacturers > Tannas & King > TFAB – Tannas Foam Air Bath
Product information
TFAB – Tannas Foam Air Bath
Category:Industrial Lubrication
Method Standard:ASTM D892,D6082, D1881, D7840,IP146
Application:Measures the tendency and stability of foam additive effectiveness in oils and lubricants over a broad temperature range.
Brand:TANNAS & King
Instrument Specifications Description Features Test Methods

Dimensions

Bench-top: 61(w) x 61(d) x 53(h) cm

 (24 x 24 x 21 inches)

Weight

~72.5 kg (~160 lbs.)

Voltage

220 VAC, Single Phase, 10 Amp.

Frequency

50/60 Hz.

Heating Medium

Air

Improved Feature

New Direct Drive motor for quiet and maintenance-free operation

Diffuser Air Flow

Stainless steel, cylindrical, diffuser stone

Pre-heated diffuser air flow system

Two (2) built-in Air Flow Meters

Air Flow Rate: 94 to 200 mL/min. (±5 mL/min.)

Operating Parameters

Temperature Range: +20°C to 175°C (±0.1°C)

Foaming Sequences: I @ 24°C

II @ 93.5°C

III @ 24°C

IV @ 150°C

Touch-Display Controller

Digital Display of Operator Commands

Audible Sequence Alarms for each measuring time

Automated Air Flow Meters programmed for each sequence

Continuous time readout

Sample Volume

200 mL

Testing Capacity

Holds six (6) 1000 mL Cylinders

Tests two (2) oil samples simultaneously

Safety

Over-temperature Cut-off Fuse & Current Limiting Fuses

Triple Pane Glass View Port

CE Marked

Shipping Weight & Dimensions

~90 kg (198 lbs.) Approximately

~71 x 71 x 122 cm (28 x 28 x 48 inches) Approximately 


High foaming tendency and slow foam collapse time are two undesirable responses of engine oils and hydraulic fluids which can result in mechanical failure. The TFAB measures the tendency and stability of foam additive effectiveness in oils and lubricants over a broad temperature range (24°C to 150°C).

The single air bath approach of the TFAB dramatically reduces bench space requirements, eliminates the need to replace oxidized (discolored) bath oil, permits more accuracy in reading foam levels, and significantly reduces the hazards of operating sequences of higher temperatures. The TFAB has shown correlation in ASTM round-robin studies and has assisted in ASTM efforts of improving the test method precision.


· The non-liquid system eliminates hazardous bath mediums from laboratory environments.

· New Direct Drive motor for quiet and maintenance-free operation.

· Thermal equivalence at all locations within bath – no temperature variations among samples.

· Removable six-position cylinder carousel; convenient side-mounted cylinder drying rack.

· New touchscreen controller and thermocouple placement for accurate control via sample temperature.

· Progressive timer with audible alarms for simplified determination of Collapse Time in D6082 test.

· Built-in cool ‘tap’ water circulation system aids cooling from higher temperature Sequences and maintains 24°C in warmer lab environments. Optional Chiller Bath available for labs without a cold tap water source nearby.


· ASTM D892 | Sequence I, II, III

· ASTM D1881

· ASTM D6082 | Sequence IV

· ASTM D7840

· IP 146

· Chinese GB/T12579

· Chinese SH/T0722